Height safety installation & certification, Melbourne.

Install, inspection, testing and certification of anchor points, static lines, guardrails and ladders — to AS/NZS 1891 and AS 1657 — by a team that uses these systems at height every day.

A duty you can't ignore

Compliant systems — installed, tested and certified.

If anyone works at height on your building — cleaners, maintenance crews, contractors — you have a duty to provide safe, compliant access and to keep it certified. Anchor points and fall-arrest systems generally need recertification at least every 12 months, and a system that isn't tested is a system you can't rely on.

360 Access installs, inspects, tests and certifies height-safety systems to the relevant Australian Standards, and gives you a documented register of every point. Because our rope-access technicians work on these systems daily, we install and assess them the way they're actually used — not from a catalogue.

Why 360 Access

A height safety installer that is audited, insured and on the rope itself.

  • ✓   IRATA International operator member (no. 4109/O) — the company, not just our technicians, is audited by IRATA on how we plan, rig, supervise and rescue.
  • ✓   ISO 9001, 14001 and 45001 certified via ATLAS (JAS-ANZ accredited), so every install and certification sits inside a documented, externally audited system.
  • ✓   $20M public liability, WorkCover in Victoria and Queensland.
  • ✓   Installers who use the systems. Our rope-access crews hang off anchor points every week, so layouts are designed from use, not from a catalogue.
  • ✓   One contractor, whole cycle. Design, install, annual anchor testing and recertification, register and tagging — no hand-off between an installer and a separate certifier.
What we provide

From install to annual certification.

Install

  • Roof anchor points
  • Static & horizontal lines
  • Guardrails, walkways & ladders

Test & certify

  • Annual inspection & load testing
  • Tagging & certification
  • Compliance register (AS/NZS 1891 · AS 1657)

Advise

  • System design & selection
  • Access strategy for your façade
  • Standby rescue capability
System types

The four systems that make a roof safe to work.

Most Melbourne buildings need a mix of systems rather than one product — the roof geometry, the façade drops and the tasks people actually perform up there decide the layout. The core system types:

  • Roof anchor points. The backbone of most height-safety systems. Surface-mount, top-fix or concrete-fix anchors rated for fall-arrest and rope-access loads, positioned so every gutter, plant item and roof edge can be reached in restraint — plus abseil-rated anchors over each façade drop for rope-access work. Selection depends on the substrate: steel purlin, concrete slab or timber structure each takes a different fixing.
  • Static lines. Horizontal lifeline systems giving continuous, hands-free attachment along a long roof run or plant corridor — the right answer where clipping anchor-to-anchor would be slow or would tempt workers to skip connections. Engineered end-loads, intermediate brackets and clear span limits, inspected as one system.
  • Ladder brackets and fixed ladders. Ladder-access brackets give portable ladders a compliant, repeatable tie-off point for low-roof access; fixed ladders handle permanent level changes, with fall-arrest rail or cage where the height requires it. Designed and checked to AS 1657.
  • Guardrails and walkways. Permanent edge protection and delineated walkways to AS 1657 — the highest-order control, because guardrail removes the fall exposure instead of arresting it. Where sightlines or heritage façades rule out fixed rail, collapsible and setback rail systems keep the roofline clean without giving the protection away.

The hierarchy of control runs through every design decision: eliminate the exposure with guardrail where practical, keep workers in restraint where it isn't, and reserve fall-arrest for the tasks that genuinely need it.

The compliance cycle

Install, inspect, recertify — the 12-month cycle.

A height-safety system isn't a one-off purchase; it's an asset on a compliance clock. Under AS/NZS 1891.4, anchorages and fall-arrest systems require inspection at intervals not exceeding 12 months — and before first use. The cycle looks like this:

  • Install or takeover. A new system is designed and installed, or an existing system is surveyed and brought under management — including systems installed by other companies.
  • Inspect. Every anchor, line, ladder point and rail is physically inspected: fixings, corrosion, deformation, and the seals and flashings at every roof penetration.
  • Test. Load and proof testing where the anchor type and standard call for it — the detail of how that works lives on our anchor point testing page.
  • Recertify and tag. Compliant points are tagged with the inspection date and next-due date, the register is updated, and the recertification documentation is issued.
  • Repeat in 12 months. The next-due date is in the register and on every tag — we track it and book the recertification before the system lapses.

On roles: we issue the inspection, testing and recertification documentation for the system — the record your building manager, owners corporation or safety auditor asks to see. Where a scope needs structural engineering sign-off (say, a retrofit fixing into an unusual substrate), that sits with the project engineer, and our documentation supports it. For the wider duty-holder picture, see our guide to height-safety compliance in Victoria.

Design that gets used

Designed for rope-access crews and maintenance workers alike.

Plenty of Melbourne roofs carry systems that exist on paper but don't work in practice: anchors in the wrong plane for the façade drop, no rated points where the abseil crew actually needs to rig, static lines that strand a worker short of the gutter. A system like that gets bypassed — which is worse than no system, because it looks like compliance. We design for both groups who will actually clip on:

  • Maintenance workers — cleaners, HVAC techs, electricians and roofing contractors. Restraint-first layouts so a worker on a lanyard can reach the gutters, plant and roof edges they service without ever entering fall-arrest, with travel paths that make the compliant route the easy route.
  • Rope-access technicians — abseil-rated primary and back-up anchors positioned over each façade drop, sane rigging clearances, rope protection at edges and deviation points where the façade steps. Because our own rope-access technicians hang off these systems every week, layouts come from use, not from a catalogue.

The payoff is commercial as well as safe: window cleaning, façade maintenance and inspection quotes come back sharper when contractors aren't pricing workarounds for a roof they can't use.

Paperwork that survives an audit

The documentation pack behind every system.

A tested anchor without a paper trail is worth little when the auditor, insurer or incoming contractor asks for evidence. Every system we install or recertify carries a defined documentation pack:

  • Asset register — a unique ID for every anchor, line, ladder point and rail, with install date, inspection and test history, and next-due date. One register for the whole building, kept current at every visit.
  • Roof layout drawing — a plan showing each point's location and ID, system limits, the access route and any exclusion zones. Issued digitally, with a durable copy at the roof access point for inducted contractors.
  • Anchor tags — every point physically tagged with its ID, inspection date and next-due date. The field rule is simple: no current tag, don't clip to it.
  • Recertification report — inspection and test findings, any defects and rectifications, and the compliance status of the system as a whole, issued after every 12-month cycle.

The pack is handed to the building manager or owners corporation records, so the system's history survives changes of manager, contractor and committee.

New build or existing roof

Height safety installation — what actually happens on the roof.

Choosing the system is the easy part. The installation is where a height safety system is either genuinely load-bearing or quietly useless, because an anchor is only ever as good as what it is fixed to. Before anything is installed we establish what the substrate actually is, which frequently isn’t what the drawings say:

  • Structural concrete — chemical or mechanical anchors set to the manufacturer’s embedment and edge distances, with cover checked so the fixing isn’t landing on reinforcement.
  • Structural steel — through-bolted to purlin or beam, sized to the member rather than to the bracket.
  • Metal deck roofing — spanning brackets that transfer load into the purlins beneath. An anchor fixed to roof sheeting alone is not an anchor, and it is one of the more common defects we find on existing systems.
  • Timber — into a verified structural member, never into battens or sarking.

Every installed anchor is proof-load tested on installation, not just at the next annual inspection — typically to 15 kN for a single-point fall-arrest anchor. It is then tagged with a unique ID and entered on the building’s register with its type, location, fixing detail and test result, so the system starts its life with a complete record rather than one assembled later from memory.

As the installer we hand the system straight into its own testing and recertification cycle, which means the same people who know how the system was fixed are the ones assessing it a year later.

Audits and inspections — what actually gets checked.

An inspection is not a walk around with a clipboard. On an existing building, a height safety audit establishes three things: what is actually up there, whether it is compliant, and whether it suits the work the building genuinely needs done.

  • The full inventory — every anchor, static line, rail, walkway, guardrail and ladder found and located, including the points nobody has a record of. Registers are very often incomplete.
  • Condition and fixing integrity — corrosion, movement, sealant failure at the penetration, and evidence the fixing is into the structure rather than the cladding.
  • Load testing — proof testing where required, with pass and fail recorded per point rather than per roof.
  • Tag-out of failures — anything that fails is physically tagged out on the day, not noted for later.
  • Coverage against actual use — whether the system reaches the elevations that actually need maintaining. A compliant system that can’t reach the façade being cleaned is a common and expensive gap.

The output is a register and report you can produce on request, which is what an insurer or a contractor refusing to work on uncertified anchors will ask for. Equipment records matter here too — a system is only half the picture if the gear clipping into it has no traceable history, which we cover in our guide to equipment inspection and records.

New buildings and retrofits are different jobs.

On a new building, the cheapest time to get height safety right is before the roof membrane goes down. We work with the builder or designer at design stage: anchor positions coordinated with the structure, cast-in or structurally integrated fixings, penetrations flashed and warranted as part of the roof build, and the whole system handed over with its register, layout drawing and initial certification — ready for the first maintenance contractor on day one, not retrofitted after the first leak or the first refused window-cleaning quote.

On an existing building — most of the work in Melbourne — the job starts with a survey of the structure and roof build-up. Fixings are selected for the actual substrate rather than an assumed one, penetrations through membrane or cladding are detailed and sealed, and any legacy system is assessed on its merits: points that pass testing are absorbed into the new register, and non-compliant points are decommissioned and clearly removed from service rather than left as a trap for the next contractor.

Either way the destination is the same: tested points, current tags, one register, one drawing — and a roof that anyone from a window cleaner to a rope-access crew can work compliantly.

Common questions

Height safety FAQs

Do you install height safety systems, or only test them?

Both. We design and install anchor points, static lines, guardrails and ladders, and we also inspect, test and recertify systems installed by other companies. Because we do the whole cycle, the install is set up for the annual recertification from day one.

How often do anchor points need to be tested?

Roof anchors and fall-arrest systems generally require inspection and recertification at least every 12 months under AS/NZS 1891.4, and before first use. We test, tag and certify with a register of every point.

Do you certify height safety systems?

Yes — we install, inspect and test anchor points, static lines, guardrails and ladders, and certify them to the relevant Australian Standards (AS/NZS 1891 for fall-arrest; AS 1657 for fixed platforms, walkways and ladders).

Who is responsible for height safety on a building?

The building owner or manager has a duty to provide safe systems for anyone working at height and keep them compliant and certified. We help you meet that with compliant systems and a current register.

How do I choose a height safety provider?

Look for certified rope-access installers who work to AS/NZS 1891 and AS 1657, who test and certify (not just supply), give you a documented register, and can also use the system day-to-day.

What load rating do roof anchor points need?

Single-person fall-arrest and rope-access anchor points in Australia are rated and proof-tested against a 15 kN benchmark, in line with AS/NZS 1891.4 and the manufacturer's specification. Every point we install or recertify is tested, tagged with its inspection and next-due dates, and recorded in the building's register.

Can you take over a height safety system installed by another company?

Yes. We inspect, test and recertify existing systems regardless of who originally installed them. The first visit builds the picture: survey every point, test what's testable, build or reconstruct the register, and document anything non-compliant with a rectification recommendation — one current record for the whole roof.

What happens if an anchor fails inspection or testing?

It's tagged out of service on the spot, recorded as failed in the register, and we recommend rectification or replacement. Compliant points elsewhere on the roof stay certified and usable — a failed anchor doesn't take the whole system offline, but it must not be used until it's rectified and retested.